|
Product Details:
Payment & Shipping Terms:
|
Model Numbe: | XB-OTS-60 | Product Name: | Corrosion Resistance Salt Spray Test Chamber , Electronic Cyclic Salt Fog Tester |
---|---|---|---|
Laboratory Temperature: | NSS.ACSS 35°C ±1°C/ CASS 50°C | PH: | 6.5~7.2 For Salt Spray Method (NSS ACSS)and 3.0~3.2 For Corrosion-resistant Testing Method(CASS) |
Controller: | OTS Designed Controller With LCD | Temp: 35±1°C For Salt Spray Method (NSS ACSS), 50±1°C For Corrosion-resistant Testing Method(CASS) S: | 47±1°C For Salt Spray Method (NSS ACSS), 63±1°C For Corrosion-resistant Testing Method(CASS) |
Material: | PVC Material | Design Standards: | IEC68-2-11,JIS,H8502,ASTM B-117-97,ISO9227,CNS3627,3885,4159,7669,8886,JIS D-0201 |
Usage: | Salt Spray Corrosion Test Chamber | ||
High Light: | environmental growth chambers,benchtop environmental chamber |
Corrosion Resistance Salt Spray Test Chamber , Electronic Cyclic salt fog Tester
Introduction
Corrosion Resistance Salt Spray Test Chamber , Electronic Cyclic salt fog Tester is used for a variety of surface treatment, including metal plating, coatings,organic and inorganic coating, anodizing, anti-rust oil, chemical corrosion resistance, and then to finished products for a long time corrosion resistance.
Specification
Model | XB-OTS-60 | XB-OTS-90 | XB-OTS-120 | XB-OTS-160 | XB-OTS-200 |
Inner size (cm) | 60x45x40 | 90x60x50 | 120x80x50 | 160x100x50 | 200x100x50 |
External size(cm) | 107x60x118 | 141x88x128 | 190x110x140 | 230x120x140 | 270x150x150 |
Inside temp | Brine test method(NSS ACSS)50°C±1°C Corrosion resistance test method. | ||||
(CASS)50°C±1°C | |||||
Brine temp | 35°C±1°C 50°C±1°C | ||||
Test chamber volume | 108L | 270L | 480L | 800L | 1000L |
Brine chamber volume | 15L | 25L | 40L | 40L | 40L |
Compressed air pressure | 1.00±0.01kgf/cm2 | ||||
Spray volume | 1.0~2.0ml/80cm2/h (Collect at least 16 hours, the average) | ||||
Test room relative humidity | 85%RH or more | ||||
PH | 6.5~7.2 or 3.0~3.2 | ||||
Spray method | Programmable spray (including the continuous spray interrupted spray) | ||||
Protective system | 1.The over temperature of whole machine. | ||||
2.Automatically cut the power off when the water level of test chamber or pressure bucket is below the standard. | |||||
3. The entire machine is set with a timer and alert of overflow, electronic leakage, light circuit. | |||||
Warranty | 12+2month(in view of transportation ,Customs be 2month),maintenance for lifelong |
Design Standard:
GB-T2423.17-1993 Humidity and salt spray test
GB/T 12967.3-91 CASS test
ASTM.B117-97 Humidity and salt spray test
GB/T 10125-2012 Corrosion tests in artificial atmospheres; Humidity and salt spray test
* GB/T 2423.18-2000 *GB/T 10125-1997 ASTM.B117-97
*JIS H8502 *DIN50021*JIS Z2371 * IEC68-2-11*QJ 2027-1990
*IEC68-2-52 1996 *GB.10587-89 *EN 14147*SH/T 0081-1991
*CNS.4158 * CNS.4159 CASS*GB/T 12967.3-91 CASS
Thermostatic control can be set under CNS, JIS, ASTM standard:
Ⅰ Humidity and salt spray test: NSS,ACSS
1) Temperature of test box: 35℃±1℃
2) Temperature of pressure bucket: 47℃±1℃
Ⅱ Corrosion resistance test: CASS
1) Temperature of test box: 50℃±1℃
2) Temperature of pressure bucket: 63℃±1℃
Supply system: the pressure is 1kg/cm²
Spray measurement 1-2mI(mI/80cm²/h)(average in 16 hours)
Spray way: Continuously.
Features:
A. The whole part of the device is made of P.V.C. Sheet and the inside of the device is reinforced by using a special lining material. Hence, it is sturdily made and will not transform forever.
B. The test chamber is heated from five directions in order to ensure the temperature difference in the chamber may be kept within (± 1℃).
C. Spray nozzle: The nozzle is specially made to enable it to suck up the salt water and then spray it out in the shape of mist with considerable high speed. When it falls on the surface of the item being tested, the difference of fallen mist may be controlled within ± 0.3ml / 80 cm2h.
D. HUNTER PRINCIPLE is used to make the saturated air hot and moist and to keep the humidity in the test chamber required for test.
E. Temperature is the pre-requisite condition that with have direct impact on corrosion rate. We use P.I.D. temperature control unit to limit the temperature difference within the range of ± 0.5℃.
F. A warning device is used to indicate the low level of the test fluid, when the fluid is only enough for being sprayed for five hours, a buzzer will remind the user to replenish the liquid to ensure continuous spray test.
G. Use full automatic detecting system, test stopped automatic, and lighting display when trouble.
Please feel FREE to contact us if you have any needs.
Custom-made ASTM B117 NSS AASS CASS Salt fog Cabinet , salt spray test chamber
Contact Person: Elina Xu
Tel: +8613829114237