Product Details:
Payment & Shipping Terms:
|
Tamp Range: | RT+10℃~+70℃ | Machine Size: | 500×1300×1460(D×W×H)mm |
---|---|---|---|
Temp Fluctuation: | ±1℃ | Temp Uniformity: | ±3℃ |
Humidity Range: | ≥95% R·H | Distance Between Lamps: | 70mm |
Size Of Standard Specimen: | 75×150mm (customized Available) | Net Weight: | 150KG |
High Light: | uv accelerated weathering tester,uv aging test chamber |
UVA / UVB Weathering Environmental Climatic Test Chamber / UV Aging Test Chamber
Chamber Structure
The inner bladder of the chamber is made of imported high-class stainless steel plate while the outer bladder is made of SUS 304 steel plate.
The heating mode adopts inner bladder trough type heating with its rapid temperature rise and even temperature distribution.
Control System:
Adopts black aluminum plate to connect temperature sensor and adopts black board temperature meter to control heating so as to ensure more stable temperature.
The radiometer probe is fixed so as to avoid the frequent installation and disassembly.
The radiation quantity adopts the special UV irradiatometer with high-precision display and measurement.
The radiation intensity is not more than 50W/m2.
The illumination and condensation can be controlled independently or alternating and circularly.
Test Specimen Mounting:
The standard test specimen holder accommodates 2 panels 75×150mm. The test panels are actual the side wall of the chamber. To properly seal the chamber, uv aging testing chamber is important to have every panel holder filled with specimens or blank panels and to have panel holders in place.
Technical Parameters :
Model | XB-OTS-UVA |
Machine size | 500×1300×1460(D×W×H)mm |
Tamp range | RT+10℃~+70℃ |
Temp fluctuation | ±1℃ |
Temp uniformity | ±3℃ |
Humidity range | ≥95% R·H |
Distance between lamps | 70mm |
Distance between samples and lamps | 50±2 mm |
Light source | UVA-340 8 pcs |
Wavelength of UV light range | 315~400nm |
Size of standard specimen | 75×150mm (customized available) |
Net Weight | 150KG |
Heating system:
1, using a U-shaped titanium alloy high-speed electric heating pipe
2, temperature control and lighting system is completely independent
3, the output power by the microcomputer temperature control algorithms to achieve high precision and high efficiency power efficiency
4, with anti-over-temperature heating system features:
(a) blackboard with color touch screen temperature control device or digital programming temperature controller buttons control the heating power output by the microcomputer calculus, PID self-tuning, monitoring blackboard using standard PT100 temperature sensor.
(b) sink temperature with color touch screen programming temperature controller heating Korea, sink located in the lower box, built-in electric heaters plus. During the test, the test section is a dark condensation process which produces saturated steam cabinets requires higher temperatures encountered when the relatively cold vapor sample surface, dew condenses on the surface of the template
Safety Devices:
Leakage protection
Power overload protection
Over-temperature protection
Voice alarm
Lack of water, ground protection
Equipment Conditions Of Use
1, ambient temperature: 5 ℃ ~ +32 ℃;
2, humidity: ≤ 85%;
3, Power requirements: AC220 (± 10%) V/50HZ One phase
4, pre-installed capacity: 5KW
Welcome to visit our factory!
Contact Person: Leslie Lei
Tel: +8613829114157