Thermal Shock Lab Test Chamber 200 Degree Temperature Recover Time ≤5min

Certification
China Dongguan Xinbao Instrument Co., Ltd. certification
China Dongguan Xinbao Instrument Co., Ltd. certification
This is my second cooperation with OTS, the machine is very good, and fast service. Look forward our next order.

—— Vinod Kumar Pandey

OTS is a very professional manufacturer for our customized machine. The quality is very surprising under such a friendly price.

—— Kohut Gabor

I visited OTS factory before order. I like their production machines, and experienced technicians. Now we have annual order from them, it is always a happy cooperation with them.

—— Chris 

I'm Online Chat Now

Thermal Shock Lab Test Chamber 200 Degree Temperature Recover Time ≤5min

Thermal Shock Lab Test Chamber 200 Degree Temperature Recover Time ≤5min
Thermal Shock Lab Test Chamber 200 Degree Temperature Recover Time ≤5min
video play

Large Image :  Thermal Shock Lab Test Chamber 200 Degree Temperature Recover Time ≤5min

Product Details:
Place of Origin: China
Brand Name: OTS
Certification: CE
Model Number: XB-OTS-80
Payment & Shipping Terms:
Minimum Order Quantity: one set
Price: Negotiable
Packaging Details: Strong standard wood case, inner plastic films wrapped for 150L High Accuracy Hot And Cold Impact Temperature Thermal Shock Test Chamber
Delivery Time: 30 working day after getting the payment
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 50 Unit/Units per Month
Detailed Product Description
Model: XB-OTS-80 Product Name: 200 Degree Environmental Thermal Shock Test Chamber IN Metal / Plastic / Rubber
Usage: Thermal Shock Test Chamber Controller: Programmable LCD Touch Screen
Compressor: Original Germany Brand Shock Temperature :: -40°C~150°C
System: P.I.D+S.S.R+Micro-coemmputer Balanced Temperature Control Refrigerant: Environmental Friendly R23/R404A
Cooling Type: Air Cooling Or Water Cooling
High Light:

climate control chamber

,

walk in environmental chamber

200 degree Environmental Thermal Shock Test Chamber IN Metal / Plastic / Rubber

 

Applicable Industries

 

200 degree Environmental Thermal Shock Test Chamber IN Metal / Plastic / Rubber that subjects a product to alternating extremes of high and low temperatures in order to observe changes in product characteristics and failure occurrence caused by different materials and their thermal expansion coefficients. Thermal shock chamber utilizes controlled areas for hot, ambient and cold temperatures. The product is moved from ambient to hot or ambient to cold zones. The chamber can be programmed to include a dwell period in the ambient zone if desired.It is applicable to metals, plastic, rubber, electronics amongst other materials. The test result can be Used as a reference or basis for product improvement.

Thermal Shock Lab Test Chamber 200 Degree Temperature Recover Time ≤5min 0

 

Specification

 

Model XB-OTS-50 XB-OTS-80 XB-OTS-150 XB-OTS-225 XB-OTS-408
Internal size WxHxD(cm)   36×40×35   40×50×40   50×60×50 60×75×50 80×85×60
External size WxHxD(cm) 148x175x160 150X175X165 155x185X165 165x200X175 185x210x185
Shock Temperature ragne -65°C~150°C
Heating up time RT~200°C about 35min
Cooling down time RT~-70°C about 90min
Temp recover time/change time ≤ 5min
Temp control accuracy ±0.5°C / ±2.0°C
distribution accuracy

 

 

Features

1.Thermal shork chamber in each zone for peak demand of heating and cooling. Provides extra thermal energy to efficiently meet the MIL-STD 883 requirements.
2.Temperature recorder provides 24 hour part temperature recording as the load travels from zone to zone. Using touch-control graph control as operation interface, easy to operate.
3.The system can be used for automatic Circulation Shock or manual selective shock, capable of setting two zones or three zones shocks as well as cold and thermal shock start-up.
4.Custom-made and optional accessories available.

 

Corresponding Standard

GB11158 GB10589-89 GB10592-89

GB/T10586-89 GB/T2423.22-2001 GB/T2423.1-2001

GB/T2423.2-2001 GB/T2423.3-93 GB/T2423.4-93

ASTM D1735 EIA - 364-59 IEC60068-2-1.1990

IEC60068-2-2.1974 IEC 68-2-30 IEC68-2-03 EIA - 364-31C

 

Safety Devices of Three-Zone High and Low Temperature Shock Simulate Chamber:

  1. Hot chamber overheat protection switch
  2. Cold chamber overheat protection switch
  3. Air circulator overload alarm
  4. Refrigerator high/low pressure protector
  5. Compressor temperature switch
  6. Air pressure switch
  7. Fuse
  8. Water suspension relay ( water-cooled specification only)
  9. Compressor circuit breaker
  10. Heater circuit breaker
  11. Test area overheat/overcool protector
  12. Air purge valve

Refrigeration operation principle

The level of the refrigeration cycle are used against the card if the cycle, which consists of two isothermal and two adiabatic processes, whose process is as follows: a refrigerant through the compressor adiabatic compression to a higher pressure, the power consumption of the exhaust gas temperature followed by the condenser refrigerant isothermal heat exchange medium in and around the heat to medium four weeks. After the refrigerant flows through the shutoff valve adiabatic expansion work, when the refrigerant temperature decreases. This loop again and again to achieve the purpose of cooling.

 

 

Air conditioning system
1) the air control: forced ventilation circulation, balance thermostat method (BTC). This method not only refers to the case of the cooling system for continuous operation, the control system according to the temperature set point of the heater to control the output of the results by automatically calculating PID output, and ultimately achieve a dynamic equilibrium.
2)air circulating means: built between the air circulation fan duct and the long axis of stainless steel, the use of energy efficient refrigerators and regulation system, by effective and efficient heat exchange ventilator, to achieve the purpose of the temperature change. By adjustable air outlet adjusting bolt, thereby significantly improving the chamber temperature uniformity;
3) the air cooling method: multi-stage diaphragm air heat exchanger.
4) air heating: Watkins quality nickel chrome electric heater.

 

Please feel FREE to contact us if you have any needs.